# 450 SystemMonitor · 系统监视器
## 用途
在同一时间轴上组合多资源折线,展示最新采样值。
## 最小示例
```go
times := []time.Time{time.Date(2026, 10, 5, 9, 0, 0, 0, time.UTC), time.Date(2026, 10, 5, 9, 0, 5, 0, time.UTC)}
metrics := []mujica.MonitorMetric{{Name: "CPU", Unit: "%", Samples: []float64{42, 51}}, {Name: "Memory", Unit: "GB", Samples: []float64{3.2, 3.4}}}
view := func(c *ui.Context) {
mujica.Use(c, mujica.Settings{})
if mujica.SystemMonitor(c, times, metrics, mujica.SystemMonitorOptions{}).Changed() {
fmt.Println("retry")
}
}
ui.Render(view, 720, 480, 1)
```
## 参数
Height 为单图高度,默认 110 DIP;Status、Error 控制加载与失败;每个 MonitorMetric.Name 必填,Samples 与 times 等长。
## 状态
实时采样、空资源、加载、失败、父级禁用。
## 事件
Changed() 表示请求重试。
## 键盘操作
Tab 到图例及图;方向键读取采样点;Home、End 到边界。
## 限制
采样由调用方提供;更新采样提交新切片;NaN 表示缺测。